Product Detail

Air Source Heat Pumps and Cold Climate Air Source Heat Pumps

Eligible air source heat pump (ASHP) and cold climate air source heat pump (ccASHP) models for the Canada Greener Homes Grant – excluding residents of Quebec and Nova Scotia who must use a separate list

To be eligible for a grant for this product, the energy advisor must have recommended a heat pump (Air Source Heat Pump, Cold Climate Air Source Heat Pump, or Ground Source Heat Pump) in the homeowner’s Renovation Upgrade Report as a way to improve the energy efficiency of the home.

Homeowners must select an eligible heat pump system by using the search options below. To confirm the eligibility of a specific system, homeowners should ask the mechanical system contractor to include the AHRI number, the brand name, and the model numbers of the indoor and outdoor units and furnace (if applicable) in the quote. This information can be used in the search options below to confirm that the quoted system is eligible.

Alternatively, homeowners may select “Download all models” to download the complete list (CSV format).

All equipment must be purchased in Canada. Online purchases are only eligible if they are ordered from an online distributor in Canada.

See the full list of eligible retrofits.

The lists are updated quarterly and were last updated on April 17, 2026.

Learn more about the searchable product list.

Return to the Canada Greener Homes Initiative Website


Outside Model HVH848GKA2*
Brand Name 1HVAC
Inside model EA*4X60L24A*+WALLCON
Furnace model *95CSU0802120A*
Rated heating capacity (Btu/hour) 45500
Grant amount $5,000: Central ducted system
AHRI / Verification reference 210469930
Product group ccASHP
AHRI Classification HRCU-A-CB
HSPF2 (Region IV) 8.5
HSPF2 (Region V) 7.1
SEER2 17.5
Series name/product line (if applicable) DELUXE 19 VS HP
Rated cooling capacity (Btu/hour) 45500
Coefficient of Performance (COP) at -15 °C (5 °F) (at maximum capacity) 2.24
Capacity Maintenance % (Max -15°C/5°F ÷ Rated 8.3°C/47°F) 70
Indoor type/ducting configuration Centrally ducted system
Model Status Active